DVH
Produces the dose volume histogram for the supplied dose matrix and structure(s). The structures can be supplied as Images (i.e. Fuzzy Masks) to ensure that the output values are accurate, or as Masks if accuracy is less important or the structures are larger. Statistics are weighted by the intensity of the Fuzzy Mask. See the Fuzzy Mask section in To Mask for a more detailed description of the concept.
Any image can be supplied to the Dose input – it is very important that the user ensures quality of the input data, i.e. that it is in fact a dose image.
Inputs
Dose
Image(s) containing the dose to be evaluated. Dose images are normally produced by importing DICOM RT DOSE, or RD files.
Type: Image, List, Required, Single
Volume(s)
Input volumes, provided as Masks or Images (Fuzzy Masks).
Type: Mask, Image, List, Required, Multiple
Outputs
DVH
A table with the DVH plot data. The first column lists the dose levels (x-axis) and each of the following columns contain the volume levels (y-axis) for a specific structure.
Type: Table
Stats
A table containing the DVH parameters. Basic parameters include image and structure information, such as names and volume. It also includes Dmin, Dmax and Dmean by defeault. It also includes other parameters that are specified in the Node Settings panel, for example D95.
Type: Table
Settings
Histogram
Prescribed Dose [Gy] Float
Set the prescribed dose (i.e. which level should represent 100% dose).
Title Text
Title of the plot.
Minimum Dose [Gy] Float
Minimum dose of the histogram.
Maximum Dose [Gy] Float
Maximum dose of the histogram.
Bins Integer
Set the number of histogram bins.
Dose DVH Statistics
D(%) [%] Numbers
Set the dose levels of interest to be explicitly displayed in the DVH Data output, specified in % of volume and output as % of prescribed dose.
D(%) [Gy] Numbers
Set the dose levels of interest to be explicitly displayed in the DVH Data output, specified in % of volume and output as absolute dose.
D(cc) [%] Numbers
Set the dose levels of interest to be explicitly displayed in the DVH Data output, specified in absolute volume and output as % of prescribed dose.
D(cc) [Gy] Numbers
Set the dose levels of interest to be explicitly displayed in the DVH Data output, specified in absolute volume and output as absolute dose.
Volume DVH Statistics
V(%) [%] Numbers
Set the volume levels of interest to be explicitly displayed in the DVH Data output, specified in % of prescribed dose and output as % of volume.
V(%) [cc] Numbers
Set the volume levels of interest to be explicitly displayed in the DVH Data output, specified in % of prescribed dose and output as absolute volume.
V(Gy) [%] Numbers
Set the volume levels of interest to be explicitly displayed in the DVH Data output, specified in absolute dose and output as % of volume.
V(Gy) [cc] Numbers
Set the volume levels of interest to be explicitly displayed in the DVH Data output, specified in absolute dose and output as absolute volume.